Sign In | Join Free | My xpandrally.com |
|
Brand Name : FUJI
Model Number : FUJIH11352 V12 working head solenoid valve
Certification : YAMAHA Vibration Vibration Fit YV YS
Place of Origin : Japan
MOQ : 1
Price : negotiation
Payment Terms : T/T,Western Union,paypal
Supply Ability : 10pcs/day
Delivery Time : 1-2 work days
Packaging Details : Woodenbox
BRAND : FUJI
model : FUJIH11352 V12 working head solenoid valve
CAPACITY : 1009
Mounter weight : 0.79kg
Mounter size : 56
supplier : CNSMT
condition : new
FUJIH11352 V12 working head solenoid valve
Our company has been in operation for 11 years and will definitely be your best choice with guaranteed quality and fast delivery
Product Introduction
FUJI H11352 – V12 Working Head Solenoid Valve
Overview
The FUJI H11352 is a pneumatically actuated solenoid valve specifically designed for the V12 working head used in FUJI NXT and NXT II/III surface mount technology (SMT) platforms. It plays a critical role in controlling the flow of compressed air that drives various head functions such as nozzle pick-up, release, and Z-axis movement.
This compact and highly responsive valve is integrated within the V12 head assembly, contributing to high-speed and precise component placement operations.
Key Features
Fast Response Time
Supports rapid actuation cycles required for high-speed SMT placement processes.
Compact & Lightweight Design
Engineered to fit inside the confined structure of the V12 working head without adding significant weight.
Airflow Control
Directs compressed air to activate actuators for nozzle suction control, head motion, or internal air switches.
Head-Specific Compatibility
Designed exclusively for use within FUJI V12 placement heads.
Long Life & Reliability
Built for continuous duty in demanding environments with millions of operation cycles.
Technical Specifications
Parameter | Description |
Part Number | H11352 |
Component Name | V12 Working Head Solenoid Valve |
Function | Pneumatic control (air switch) |
Mounting | Inside V12 head (internal module) |
Air Supply | Clean, dry compressed air (regulated) |
Operation Type | Electric signal-controlled valve |
Compatible Heads | FUJI NXT / NXT II / NXT III – V12 Working Head |
Applications
Controls nozzle suction ON/OFF
Actuates Z-axis or internal mini cylinders
Part of the air-driven motion system inside the head
Ensures accurate component pickup, placement, and release
Maintenance & Handling Tips
Ensure clean, moisture-free air is supplied to avoid clogging or corrosion.
Inspect for signs of sticking, noise, or slow actuation.
Replace during preventive head maintenance if responsiveness drops.
Always follow FUJI’s ESD and cleanroom handling protocols during replacement.
Related Components
Component Name | Description |
V12 Working Head Assembly | Main head that houses the solenoid valve |
Valve Cable Connector / Harness | Electrical connection to machine control board |
Pneumatic Tubing / Air Line | Delivers compressed air to the valve |
Mini Cylinder or Air Actuator | The output device actuated by the valve |
Head PCB Control Unit | Sends solenoid control signal |
Valve Mounting Plate or Housing | Secures the valve inside the head structure |
Related Accessories for FUJI H11352 V12 Solenoid Valve
Accessory Name (EN) | Description |
V12 Head Internal Air Tubing | Delivers compressed air to and from the solenoid valve. Usually made of flexible polyurethane. |
Solenoid Cable Harness / Connector | Electrical wire set that connects the valve to the head control PCB for signal transmission. |
Mini Pneumatic Cylinder / Actuator | The component driven by the valve; used for nozzle up/down motion or internal shifting. |
Air Fitting / Push-in Connector | Connects air tubing to the solenoid valve securely and allows quick replacement. |
Valve Mounting Screw or Bracket | Fasteners or metal base that physically secures the valve inside the V12 head assembly. |
V12 Head Control PCB (Driver Board) | Sends control signals to the solenoid valve and monitors feedback. |
Inline Air Filter (Miniature Type) | Prevents debris or oil from reaching the valve to extend service life. |
Nozzle Shaft or Pickup Unit | Mechanically actuated part whose motion is triggered by the air valve. |
Exhaust Muffler / Air Silencer | Reduces exhaust noise and prevents particle backflow into the valve outlet. |
ESD-safe Installation Tool Kit | For safe disassembly, installation, and ESD protection during solenoid service. |
These parts work together to ensure precise air control, rapid actuation, and long-term stability of the V12 working head’s pneumatic functions.
Related Part Numbers for FUJI H11352 V12 Solenoid Valve
Component Name (EN) | FUJI Part Number (Example) | Description |
Solenoid Valve | H11352 | Main solenoid valve used inside V12 head |
Solenoid Valve Cable Harness | XH02919 (example) | Connects valve to head control PCB |
Pneumatic Air Tube (PU 4mm/3mm) | XH00715 (example) | Flexible tubing delivering air to the valve |
Quick Air Fitting (Straight/Elbow) | XG54120 (example) | Connects air tube to solenoid ports |
Mini Cylinder for Nozzle Movement | H11603 (example) | Driven by the solenoid for nozzle actuation |
V12 Head Driver PCB (Control Board) | AA1C2D00 (example) | Sends signal to control solenoid functions |
Mounting Screw or Bracket Set | XA90745 (example) | Secures solenoid valve inside the head |
Inline Miniature Air Filter | XG60052 (example) | Removes impurities from air line before valve |
Exhaust Silencer (M5 Thread Type) | XG61800 (example) | Reduces noise on solenoid valve outlet |
Pickup Shaft (Nozzle Unit Base) | AA4PA00 (example) | Mechanically interacts with valve-actuated motion |
Note: Part numbers marked with (example) are frequently used in FUJI V12 head assemblies but may vary depending on model version or region. Always cross-check with FUJI’s official parts catalog or your equipment supplier.
FAQ Guide – FUJI H11352 V12 Working Head Solenoid Valve
1. What is FUJI H11352?
Answer:
The FUJI H11352 is a pneumatic solenoid valve installed inside the V12 working head of FUJI NXT/NXT II/NXT III placement machines. It controls the flow of compressed air to various internal actuators within the head, enabling precise control of nozzle movements such as suction, release, and Z-axis motion.
2. What does this solenoid valve do?
Answer:
It electrically switches air on/off to control pneumatic functions inside the V12 head, such as:
Nozzle vacuum control (suction/release)
Z-axis actuation (up/down movement of nozzle shaft)
Internal cylinder movement for mechanical positioning or switching
Its fast switching speed ensures reliable and repeatable high-speed placement.
3. Where is it located?
Answer:
The H11352 valve is mounted inside the V12 head assembly, usually near the pneumatic control block. It connects to both electrical signal cables and air supply tubing.
4. What are the symptoms of a faulty H11352 valve?
Answer:
Nozzle cannot pick up or release components
Air leakage sound from inside the head
Slow or no nozzle movement on Z-axis
Error messages related to suction failure or head malfunction
Irregular air response or weak vacuum pressure
5. How is it maintained or replaced?
Answer:
Inspect the valve during regular head maintenance cycles
Check for air leaks, loose fittings, or delayed actuation
Replace the valve if it shows signs of clogging, slow response, or electrical failure
Use ESD-safe tools and clean, dry compressed air
After replacement, test nozzle motion and suction
6. What is the air pressure requirement?
Answer:
The solenoid valve typically operates under 0.45 MPa to 0.60 MPa clean, dry compressed air. Ensure regulated supply to prevent valve failure or head malfunction.
7. Can it be replaced individually?
Answer:
Yes, the H11352 can be replaced independently without removing the full head.
Ensure you:
Disconnect the signal cable and air lines
Unscrew or release the valve from its mounting bracket
Reinstall using original FUJI-compatible parts and torque specs
8. What components work with it?
Part Name | Part Number (Example) | Description |
Solenoid Valve | H11352 | Main air-control valve |
Solenoid Cable Harness | XH02919 (example) | Connects valve to control board |
PU Air Tubing (4mm) | XH00715 (example) | Air supply line for valve |
Mini Cylinder (Nozzle Control) | H11603 (example) | Actuated by valve air |
Quick Air Fitting Connector | XG54120 (example) | Push-in connection to valve ports |
Mounting Bracket / Screws | XA90745 (example) | Fixes valve into the V12 head |
V12 Head Control PCB | AA1C2D00 (example) | Sends control signal to the valve |
9. What causes solenoid valve failure?
Answer:
Contaminated air supply (oil, dust, moisture)
Overvoltage or broken wiring in the control signal
Excessive cycle fatigue from long-term use
Improper handling during head disassembly or cleaning
10. How often should it be checked?
Answer:
During scheduled head maintenance (typically every 3–6 months depending on production volume)
Immediately if suction failure, head error, or air leakage occurs
After a head refurbishment or nozzle system cleaning
Ordering & Compatibility Notes
Confirm that your head model is V12 – not V8, V4, etc.
Always use original FUJI parts to maintain performance and vacuum integrity
Replacement part number: H11352
Contact:
CNSMT Electronics Equipment Co,.LTD
Email: info@smtlinemachine.com
www.smtlinemachine.com
Mb/whatsapp/wechat:+8613537875415
SKYPE:smtdwx
![]() |
Genuine FUJI H11352 V12 Working Head Solenoid Valve for SMT Machines Images |